Vladimir Steshin created IGNITE-13015:
-----------------------------------------

             Summary: Use nono time instead of currentMills() in node failure ddetection.
                 Key: IGNITE-13015
                 URL: https://issues.apache.org/jira/browse/IGNITE-13015
             Project: Ignite
          Issue Type: Improvement
            Reporter: Vladimir Steshin
            Assignee: Vladimir Steshin


Make sure in node failure detection not used:
{code:java}
System.currentTimeMillis()
and
IgniteUtils.currentTimeMillis()
{code}

Disadventages:

1) Current system time has no quarantine of strict forward movement. System time can be adjusted, synchronized by NTP as example. This can lead to incorrect and negative delays.

2) IgniteUtils.currentTimeMillis() is granulated by 10ms



--